Do You Have Any Questions?

Toll-free (in the US): 1-866-ENDEVCO
Fax: 1-716-684-0987
Contact Endevco

We found 11 matches....
Model: 2950M3

Model: 2950M3

Accessories, Triaxial mounting block, 6-32 threaded holes (potentially for 2221F, 7221A, 7251A), 4-40 mounting screws

    Model: 7251A-10

    Model: 7251A-10

    Accelerometer, IEPE, 10 mV/g, ±500 g, -67°F to +257°F, isolated, thru-hole mount, side connector, 10.5 grams

      Model: 7251A-10-R

      Model: 7251A-10-R

      Accelerometer, IEPE, 10 mV/g, ±500 g, -67°F to +257°F, isolated, thru-hole mount, side connector, 10.5 grams, no cable incl.

        Model: 7251A-100

        Model: 7251A-100

        Accelerometer, IEPE, 100 mV/g, ±50 g, -67°F to +257°F, isolated, thru-hole mount, side connector, 10.5 grams

          Model: 7251A-100-R

          Model: 7251A-100-R

          Accelerometer, IEPE, 100 mV/g, ±50 g, -67°F to +257°F, isolated, thru-hole mount, side connector, 10.5 grams, no cable incl

            Model: 7251A-50

            Model: 7251A-50

            Accelerometer, IEPE, 50 mV/g, ±100 g, -67°F to +257°F, isolated, thru-hole mount, side connector, 10.5 grams

              model 7251a datasheet_v01-06-20.pdf

              model 7251a datasheet_v01-06-20.pdf

              Isotron ® accelerometer Model 7251A ENDEVCO www.endevco.com Tel: +1 (866) ENDEVCO [+1 (866)

              model 7251a datasheet_v01-06-20.pdf

              model 7251a datasheet_v01-06-20.pdf

              Isotron ® accelerometer Model 7251A ENDEVCO www.endevco.com Tel: +1 (866) ENDEVCO [+1 (866)

              
	What happens when the constant current source and compliance voltage of an IEPE accelerometer varies outside the specification limits?

              What happens when the constant current source and compliance voltage of an IEPE accelerometer varies outside the specification limits?

              model 7251A data sheet: Supply voltage = 23Vdc to 30Vdc Bias specification = 12.5Vdc to 13.5Vdc (use 13.5Vdc for worst case bias) Full scale output voltage = 5V Typical charge amplifier characteristics: Amplifier output non-linearity 3V (for simplicity, this term was ig

              auto-testing-brochure.pdf

              auto-testing-brochure.pdf

              Automotive testing Endevco accelerometers are used in vehicle dynamic testing of engines, exhaust s

              edv-catalog_lowres.pdf

              edv-catalog_lowres.pdf

              TEST & MEASUREMENT SENSOR CATALOG EXTREME ENVIRONMENTS Accelerometers Pressure transducers Signa