Model: 7703A-100

Model: 7703A-100

Accelerometer, PE, 100 pC/g, radiation hardened, -67°F to +550°F, isolated, 10-32 mounting stud, side connector, 29 grams

    Model: 7703A-100-R

    Model: 7703A-100-R

    Accelerometer, PE, 100 pC/g, radiation hardened, -67°F to +550°F, isolated, 10-32 mounting stud, side connector, 29 grams, no cable incl.

      Model: 7703A-1000

      Model: 7703A-1000

      Accelerometer, PE, 1000 pC/g, radiation hardened, -67°F to +550°F, isolated, 10-32 mounting stud, side connector, 120 grams

        Model: 7703A-1000-R

        Model: 7703A-1000-R

        Accelerometer, PE, 1000 pC/g, radiation hardened, -67°F to +550°F, isolated, 10-32 mounting stud, side connector, 120 grams, no cable incl.

          Model: 7703A-200

          Model: 7703A-200

          Accelerometer, PE, 200 pC/g, radiation hardened, -67°F to +550°F, isolated, 10-32 mounting stud, side connector, 62 grams

            Model: 7703A-200-R

            Model: 7703A-200-R

            Accelerometer, PE, 200 pC/g, radiation hardened, -67°F to +550°F, isolated, 10-32 mounting stud, side connector, 62 grams, no cable incl.

              Model: 7703A-50

              Model: 7703A-50

              Accelerometer, PE, 50 pC/g, radiation hardened, -67°F to +550°F, isolated, 10-32 mounting stud, side connector, 25 grams

                Model: 7703A-50-R

                Model: 7703A-50-R

                Accelerometer, PE, 50 pC/g, radiation hardened, -67°F to +550°F, isolated, 10-32 mounting stud, side connector, 25 grams, no cable incl.

                  
	Using single-ended accelerometers with the 2777A differential charge amplifier

                  Using single-ended accelerometers with the 2777A differential charge amplifier

                  with 7703A's that have single-ended outputs. We are also using 2777A differential charge amplifiers. Can I use the 2777A with the 7703A, or do I have to replace the charge amplifiers? Answer Yes. You can make the differential input into a single-ended input by connecting Pin B, of the input pl

                  
	Infrastructure

                  Infrastructure

                  sure (7703A), hermetic sealing against contaminants while maintaining TEDS compliance (41A19-5), or measurement in 3 axis (45A). For those more general applications, the 43A is a good choice as its unique cube shape allows the sensor to be mounted in two different orientatio

                  featured-products-brochure.pdf